The Smart Alarm LED shows how big or small a leak is on a scale of one to nine:
- 1 to 3 – less than 0.1 oz./yr.
- 4 to 6 – 0.1 to 0.5 oz./yr.
- 7 to 9 – more than 0.5 oz./yr.
- If there is no response from the flashing tip or beeping signal at the preset normal sensitivity in the general area of a suspected leak, select high sensitivity
- High sensitivity will detect even low levels that could be missed with other detection systems
- Use low sensitivity as you move the tip over more defined areas of a system
- Long life, stable sensor
- Instantaneous response time
- Clears quickly from large amounts of refrigerant
- Automatic calibration and reset to ambient
- Low battery indicator
- Leak Test Vial included to verify proper functioning of detector
- 18-month limited warranty (12-month warranty on sensor)
- Made in the USA
- Sensitivity: 0.06 oz./yr. (1.7 g/yr.) HFCs R-134a, 0.03 oz./yr. (0.9 g/yr.) HCFCs R-22
- Heated electrochemical sensor: Over 300 hours service life with minimal cleaning and no adjustments
- Maintenance required: None
- Body length: 10" (25.4 cm)
- Probe length: 18" (46 cm)
- Weight: 15 oz. (0.4 kg)
- Warm up time: 25 seconds or less
- Power: 4 AA alkaline batteries, 8 hours continuous life
- Operating temperature range: 24° to 110°F (-4° to 43°C)
- Storage temperature range: -4° to 122°F (-20° to 50°C)
- Approvals: SAE J1627, SAE J2791, CE, EN 14624