PRINT | CLOSE WINDOW
1/4" Flexible Hoses
• Easily connects to 1/4" Male flare access fitting on system

1). YELLOW JACKET Original 1/4" Charging Hose

• All-weather flexible
• Dependable
• Adjust-a-Valve™ Opener – Patented valve core depressor allows you to easily open all troublesome, out of tolerance Schrader valves. 
 
Temperature: -20° to 180°F (-28.8° to 82.2°C)
Burst: 2500 psi (172 bar) minimum
Working: 500 psi (34 bar) maximum
Safety factor: 5 to 1
Available lengths: 6" to 100'


2). YELLOW JACKET PLUS II ™ 1/4" Charging Hose (Seal Right™, FlexFlow and Ball-Valve ends) 

• Adjust-a-Valve™ Opener – Patented valve core depressor. Easily open all out of tolerance Schrader valves. (SealRight hoses offer different technology.)
PLUS II ™ hoses offer double barrier protection:
– Nylon permeation barrier meets UL requirements.
– Moisture barrier provides improved resistance to moisture migration, which contaminates expensive refrigerants.
• Rubber layer for permeation, braid for strength, and outer cover for protection.
• Fully UL recognized assemblies (File SA9737).   

Temp: -20° to 180°F (-28.8° to 82.2°C)  
Burst: 4000 psi (276 bar) minimum
Working: 800 psi (55 bar) maximum
Safety factor: 5 to 1
Available lengths: 12" to 100'



3/8" Flexible Hoses
• Evacuates and charges 4 times faster than 1/4" hose

1). YELLOW JACKET PLUS II ™ 3/8" Charging Hose
  
PLUS II ™ Hoses with double barrier protection:
– Nylon barrier meets UL permeation requirements.
– Moisture barrier provides improved resistance to moisture migration, which contaminates expensive refrigerants.
– Higher working pressure.

Temp: -20° to 200°F (-28.8° to 93.3°C)
Burst: 3000 psi (207 bar) minimum
Working: 600 psi (41 bar) maximum
Safety factor: 5 to 1
Available lengths: 12" to 100'



1/2" and 5/8" Flexible Hoses
• Evacuates and charges 8 times faster than 1/4" hose
• Allows you to pull a deeper vacuum
• More efficient job of removing moisture and contaminants from the system

1). YELLOW JACKET PLUS II ™ 1/2" and 5/8" Charging Hose

PLUS II ™ Hoses:
– Nylon barrier meets UL permeation requirements.
– Moisture barrier provides improved resistance to moisture migration, which contaminates expensive refrigerants.
• Large ID reduces vacuum time substantially over 1/4" or 3/8" hose – allowing techs to pull a faster vacuum.
• Faster refrigerant transfer and faster charging on large systems.
• Wide selection of fittings are available.
• Operating temperature -20° to 200°F.

Temp: -20° to 200°F (-28.8° to 93.3°C)
Burst: 3000 psi (207 bar) minimum
Working: 600 psi (41 bar) maximum
Safety factor: 5 to 1
Available lengths: 12 inches to 100 feet